Drager CMS Analyzer with Remote System
|
|
Customer Price: $2,820.00
Usually Ships in 2-5 Business Days
Item Number: 8317700
Manufacturer: Draeger
Manufacturer Part No: 8317700
|
|
Simple to use
The Draeger CMS is ready for use after only a brief instruction. It makes no difference which gas or vapor you wish to measure – the instrument is used in the same way every time. The operation is guided by a menu on the display and a single button/switch. The display can be backlit and is available in German, English, French or Spanish. After an automatic system self-test, the analyzer is powered up and the measurement system is immediately ready for operation.
Simply insert the chip (each chip can conduct 10 tests), perform the measurement and read the measurement result displayed as a concentration on the screen. At the end of the measurement, the chip is automatically ejected from the instrument, and the analyzer shuts down. An audible signal sounds after each operating step. The on-board data-recorder stores up to 50 measurements with the gas/concentration and date/time. The recorder can be set up to record manually or automatically, and previous measurements can be called up on demand.
Power is supplied by four standard and easily replaceable batteries which are especially suited to the analyzer's requirements (see technical data). The battery capacity allows for more than seven hours of measurement and is, of course, always displayed on the screen.
The Dräger CMS is currently used extensively in the petrochemical, transportation, and utilities industries as well as the fire service and government regulatory agencies. Popular applications include TWA screening, confined space entry and emergency response.
Accurate
The principle of mass current measurement ensures that the instrument remains unaffected by fluctuations in air pressure. Because the chips are calibrated before leaving the factory, there is no need for the user to calibrate the Dräger CMS. Any possible temperature and humidity effects are checked during factory calibration. The analyzer is explosion
protected and certified in accordance with Cenelec (Europe), UL (USA) and UL/CSA (Canada). In addition, the system is protected against dust and splash water in accordance with IP 54, and is resistant to electromagnetic waves.
TECHNICAL DATA
Measurement range and resolution Depends on chip type used - please see chip list
Typical measurement time 30 s to 5 min in range of the limit values,
depends on chip type and concentration
of hazardous substance
Ready for measurement Immediately
Poisoning effects Not possible
Calibration Not necessary
Temperature during operation 0 to 40°C
Temperature during storage -20 to +60°C (analyzer) < 25°C (chips)
Air pressure 700 to 1100 hPa
Humidity 0 to 95% relative humidity, non-condensing
Recording of measured values Six-fold optics and light conductor system,
remission measurement
System diagnosis Automatic, with micro controller for all
system components
Display LCD, alphanumeric with back lighting
Menu languages English, German, French, Spanish
Operating time Approx. 450 minutes of measurement
Power supply Varta LR 6 4006
4 x 1.5 V batteries from the following types: Energizer LR 6 E 91
Panasonic LR 6 AM 3 AA MN 1500
Alkaline/foil (PMBC)
Weight 730 g (analyser with batteries)
Dimensions (LxWxH) 215 mm x 105 mm x 65 mm
Approvals: BVS Europe type examination certificate, protection class EEx ib II CT4,
test no. BVS 95.D.2109
UL USA Class 1, Div. 1, Groups A, B, C, D, Temp. Code T4, 2P91
UL Canada Class 1, Div. 1, Groups A, B, C, D, Temp. Code T4, 2P91
CSA Canada Class 1, Div. 1, Groups A, B, C, D, Exia, Temp. Code T4
Protection class IP 54 dust and splash protection
•CMS Analyzer with Integral Remote Pump
***Remote factory installed –service by authorized service technician only!!
•3 Meter Extension Hose with Adapter
•Float Probe
|